Specification Sheet

Water Pressure
Water Connection
Integral Water Values
Water Supply Requirements
Total Dissolved Solids (TDS)
Integral Water Filter
Power Rating
Power Supply Requirements
Dimensions (WxDxH)
Minimum Air Gap
Dry Weight
Product Approvals
Warranty
CO2 Cylinder
CO2 Capacity
CO2 Operating Pressure
Maximum Hose Connection
Length
Minumum Distance Needed for
Installation
Recommended Cabinet Depth
BCS120V - COMMAND CENTER SPECSBCS120V - COMMAND CENTER SPECS
Min 36psi – Max 75psi with a minimum ow rate of 1 gpm
½” BSP - isolation valve is required within 3’ of the installation
HydroTaps are tted with a dual check valve and a 50psi pressure limiting valve
Potable drinking water supply
TDS minimum 50ppm – maximum 120ppm
0.2 micron, 1 size - replace every 1,500 gallons or 12 months
110-120V, 60 Hz, 1.25kW, 9A draw
110-120V, 60Hz 15A power supply with a NEMA 5-15 outlet
13.4” x 18.2” x 13.1”
Clearances are required - 2” left side , 2” right side , 8”above
79.36lbs
IAPMO - NSF/ANSI 372, 42 & 53, cUL, CEC
2 years (1 year limited warranty plus additional 1 year warranty is available on product registration)
2 x 1.5lb beverage-grade carbon dioxide cylinder
Approximately 450 glasses of sparkling water per 1.5lb CO2 cylinder
Min 39psi - Max 43psi
3’ (tap to command center)
15” (interior wall to disposal)
24”
HYDROTAP
®
ARC FOR HOME
Installation and connection of your HydroTap must be carried out by a qualied person, observing all local, state, & federal regulations. You will require suitable 110 -120V 60Hz 15 amp power supply with a NEMA 5-15
electrical outlet within 3’ of the product. The HydroTap is a pump-driven system so the installation of the Tap must be within 3’ of the base command center. The HydroTap is an air-cooled system so discrete cabinetry
cut-outs are required for ventilation. Installation on most countertops is straightforward however some stone countertops may require a specialized cutting service. If using a drip tray (font) accessory, suitable drainage to
a trapped waste is required within 3’ of the installation. If you live in an area with hard water (more than 120ppm), we recommend installation of a scale ltration kit. Sufcient space and clearance to install the HydroTap
as detailed in the product installation guidelines is required. Installation by Zip Professional Service can be arranged with a phone call to 1-833-233-2358 or through https://us.zipwater.com.
A
A
Mains cold water
isolation valve
(not supplied)
CO gas
cylinder
2
IEC Flex & Plug
110-120V, 60Hz
power outlet
Position the Tap to dispense into the sink
bowl with ample clearance for a cup or a carafe.
Alternatively, the Tap may be mounted away from
the sink using a Zip Font, available as an accessory.
1
8
Sample
Tap
SECTION A-A
3mm ( )
buffer pad
air space
11.5"
(292
mm
)
(461mm)
18.2"
(82mm)
3.2"
2.0"
min
(50mm)
2.0"
min
(50mm)
13.4"
min
(339mm)
Clearance
Envelope
1
8
8 "
(207mm)
DETAIL B: CABINET FLOOR CUT-OUT
VENTILATION DETAIL
See Detail B
7.9"
min
(200mm)
(333mm)
13.1"
min
1 "
hole
Sink shown only
3
8
(35mm)
11
16
1 " max
15
16
12
"
(326mm)
3
16
"
(5mm)
(43mm)
2021ZIP_ArcBCS_120v_v1