User's Manual
Uniwave Initial System Setup
User Manual
Copyright © 2022 Zinwave. All rights reserved. 10-8
have such a device set this field to 0.0.0.0.
10.6.3 SNMP Settings
Trap IP Address
The network address to which traps are to be sent. This would usually be the network management computer.
Setting this field to 0.0.0.0 disables traps.
Trap Port
The UDP port number to which traps are sent. For most systems this will be 162.
Trap Type
SNMP traps can be configured to use either the “Trap” or “Inform” transport mechanism. “Trap” is more widely
supported, but “Inform” provides additional reliability.
RO Community
SNMP Read-Only Community string is the password that must be used by an SNMP Manager to gain SNMP
GET Request access to the Hub. This should be changed from the default value of "public" if SNMP access is to
be secured.
RW Community
SNMP Read-Write Community string is the password that must be used by an SNMP Manager to gain SNMP
SET Request access to the Hub. This should be changed from the default value of "private" if SNMP access is to
be secured.
10.6.4 User Interface Settings
Connection Encryption (SSL)
Connection encryption for the browser can be set to enabled (https) or disabled (http).
This determines whether browser connections must use an encrypted (https) or unencrypted (http) connection.
Note: On changing this setting, the user will be required to log back into the GUI.
10.6.5 Date & Time
The date and time used by the Hub can be configured.
NTP Client
This enables or disables the Network Time Protocol (NTP) feature. When enabled, the Hub will fetch the current
time from a time server on the local network or the internet.
If NTP is enabled, the Time and Date settings will be disabled.
NTP Server