Technical Specifications
Tinting – Improve hiding power of the topcoat – tint toward topcoat color with up to 2 oz. (59 ml) universal colorant per
gallon (Note that the addition of universal colorant may prolong the dry time of this product).
Thinning – If thinning is necessary add no more than 10 fl. oz. (296 ml) clean water per gallon and stir thoroughly. Note
that thinning the primer may affect its stain-blocking properties.
Dry Time – To touch in 30 minutes; Recoat in 1 hour. Allow 2 hours for interior stain blocking and overnight for exterior
stain blocking. Full adhesion and hardness develop in 7 days. Lower temperatures, higher humidity and the addition of
tint will prolong dry and cure time.
Coverage – Approx. 400 sq. ft. (37 m²) per gallon on smooth, painted, non-porous surfaces; 350 sq. ft. (33 m²) per
gallon on rough, unpainted, porous surfaces. Application losses may vary according to the porosity of the substrate and
the method of application and should be taken into account when estimating the quantity of product needed.
Cleanup – Clean up spills and drips with liquid detergent and warm water. If spills or drips have dried use denatured
alcohol or ammoniated detergent to soften and remove primer. Wash application tools in a solution of detergent and
water immediately after use. If dried on tools let soak overnight in a solution of equal parts ammoniated detergent and
water. Scrub bristles clean with a wire brush. Follow manufacturer’s instructions when cleaning spray equipment.
Caution
Do not get in eyes. Flush eyes with plenty of water for at least 15 minutes. Do not take internally. If swallowed call a
physician or Poison Control Center. Do not breath in vapors or spray mist. Ensure good cross ventilation during
application and drying. If you experience difficulty in breathing, eye watering, headache, or dizziness, increase fresh air;
wear an appropriate, properly fitted (NIOSH approved) respirator; or leave the area and obtain fresh air. Avoid contact
with skin and clothing. Wash thoroughly after handling. Warning: This product contains a chemical known to the state of
California to cause cancer and birth defects, or other reproductive harm. Keep container closed when not in use. KEEP
OUT OF REACH OF CHILDREN.
Limited Warranty –
Bulls
Eye
1-2-3
plus is guaranteed to perform as indicated when applied according to label
directions to a properly prepared surface. Directions are as complete as possible but cannot encompass all conditions,
applications, and/or surfaces beyond manufacturer’s control. The contents of the container are warranted to be free from
any other defect for 2 years from the date of manufacture. All warrantees and guarantees are limited to refund or
replacement of product used with proof of purchase. No other warranty or guarantee is expressed or implied.
Typical Physical Properties
Percent Solids, Weight:
Percent Solids, Volume:
Density:
Viscosity Range:
Theoretical Spread Rate @
1 mill DFT:
Flame Spread (ASTM-84-97A):
Smoke Contrib.
(ASTM-84-97A):
Flash Point (ASTM D3278):
VOC:
LEED:
50.9%
35.2%
10.8 lb./gal
95 to 100 KU
540 sq. ft (50m²)/gal
Class A
Class A
>200°F (93° C)
0 g/L
Meets 4.2 Requirements
Dry Time @75° F / 50% RH:
Stain Sealing @ 75° F/ 50% RH:
Adhesion Cure @ 75° F/50% RH:
Cured Gloss @ 85°:
Cured Enamel Holdout:
Cured Wet Adhesion:
Cured Flexibility (1/4”Mandrel):
Freeze/Thaw Stable:
Shelf Life:
Storage/Handling:
Touch: 30 min
Recoat: 1 hour
2 hours
24 hrs over cedar
7 days
5.0
1.5% g
Pass 2000 cycles scrub
Pass /5A
Yes
60 mo @ 75°F (24°C)
Store indoors
40° - 90° F
(4° - 32°C)
Disposal – Dispose of unused or unwanted product in accordance with local laws regulating water-based coatings.
Limitations – Not recommended for floors or decks or surfaces subject to immersion or prolonged contact with water.