User manual
! !!
!
18"
ZIG&POE&RXAV"USER"MANUAL!
!
Status
Local HDBaseT (RXAV in this case)
• Link – Green when there is an HDBaseT connection
• HDMI - Green when HDMI is present
• Mode: Solid green when HDCP is present, flashing green when no HDCP
detected.
• Cable Length of CAT cable being reported by HDBaseT chip – this is not
always 100% accurate, especially with shorter cables.
Remote HDBaseT (POEWP in this case)
• Link – Green when there is an HDBaseT connection
• HDMI - Green when HDMI is present
• Mode: Solid green when HDCP is present, flashing green when no HDCP
detected.
• Cable Length of CAT cable being reported by HDBaseT chip – this is not
always 100% accurate, especially with shorter cables.
Device Name & Notes
• Device Name – default out of the box is ZIG-POE-RXAV.XXXX (last 4
digits of the serial number). You should change it if you are using more
than 1 device (Change Name below) to whatever you want – ex.
CR100RX – for conference room number 100 receiver.
• Notes – free form field for entering installer notes.
Control/Defaults
• Relay 1 – checking box changes the state of the relay. NC-G-NO
• Relay 2 – checking box changes the state of the relay. NC-G-NO
• Audio Mute – Mutes the audio from the built-in amplifier.
• Volume Control – Control volume
• Bass – Control the bass of the audio
• Treble – Control the treble of the audio
• RS232 Baud Rate – use to match the speed of your 3
rd
party control
system.
Firmware/Reset/Info