User Manual
Note: the device will be removed from the network and all bindings will be cleared.
2. Removing from a Zigbee Network
Press and hold the Prog. button until LED indicator blinks 4 times slowly, then release the button, LED indicator will then
stay solid on for 3 seconds to indicate that the device is removed from the network successfully.
1. Zigbee Network Pairing
Step 1: Remove the device from previous zigbee network if it has already been added to, otherwise
pairing will
fail. Please refer to the part " Factory Reset Manually" .
Step 2: From your ZigBee gateway or hub interface, choose to add device and enter Pairing mode as instructed by the
gateway.
Step 3: Method 1: short press the “Prog.” Button 3 times continuously within 1.5 seconds, the LED indicator will flash
rapidly and enter into network pairing mode (beacon request) which lasts for 60 seconds. Once timeout, repeat this step.
Method 2: make sure the device has not paired to any Zigbee network, reset power of the device by removing the
batteries and installing them again, then the device will enter into network pairing mode automatically which lasts for 10
seconds. Once timeout, repeat this step.
Operations
Step 4: The LED indicator will stay solid on for 3 seconds if the device is paired to the network successfully, then the
device will appear in your gateway's menu and can be controlled through gateway or hub interface.
Note: factory reset will remove the device from the network, clear all bindings, restore all parameters to factory default
setting, clear all report config settings.
3. Factory Reset Manually
Press and hold the Prog. button for over 10 seconds, during the process, the LED indicator will blink slowly at the
frequency of 0.5Hz, the LED indicator will stay solid on for 3 seconds which means factory reset successfully, then LED
will turn off.
4. Check Whether the Device is Already in a Zigbee Network
Method 1: short press Prog. button, if LED indicator stays solid on for 3 seconds, this means the device has already
been added to a network. If LED indicator blinks 3 times slowly, this means the device has not been added to any
network.
Method 2: reset power of the device by removing the batteries and installing them again, if the LED indicator blinks
rapidly, it means the device has not been added to any network. If LED indicator stays solid on for 3 seconds, this means
the device has not been added to any network.
5. Wireless Data Interaction
Since the device is a sleep device, it needs to be awakened.
If the device has already been added to a network, when there is a button trigger, the device will be awakened, then if
there is no data from the gateway within 3 seconds, the device will go to sleep again.
Zigbee Interface
1. Zigbee application endpoints:
Endpoint
0(0x00)
1(0x01)
2(0x02)
Application
ZigBee Device Object (ZDO) – standard management features
Occupancy Sensor, power, OTA, DeviceID = 0x0107
IAS Zone(), DeviceID = 0x0402
Profile
0x0000 (ZDP)
0x0104 (HA)
0x0104 (HA)
3(0x03)
4(0x04)
5(0x05)
Temperature Sensor, DeviceID = 0x0302
Humidity Sensor, DeviceID = 0x0302
Light Sensor, DeviceID = 0x0106
0x0104 (HA)
0x0104 (HA)
0x0104 (HA)
1.1 Application Endpoint #0 –ZigBee Device Object
• Application profile Id 0x0000
• Application device Id 0x0000
• Supports all mandatory clusters
1.2 Application Endpoint #1 –Occupancy Sensor
Cluster Supported Description
0x0000 server
Basic
Provides basic information about the device, such as the manufacturer ID,
vendor and model name, stack profile, ZCL version, production date, hardware
revision etc. Allows a factory reset of attributes, without the device leaving the
network.
0x0001
server
Power Configuration
Attributes for determining detailed information about a device’s power
source(s) and for configuring under/over voltage alarms.
0x0003
server
Identify
Allows to put the endpoint into identify mode. Useful for identifying/locating
devices and required for Finding & Binding.
0x0009
server
Alarms
0x0019 Client
OTA Upgrade
Pull-oriented firmware upgrade. Searches the network for mating servers and
allows the server to control all stages of the upgrade process, including which
image to download, when to download, at what rate and when to install the
downloaded image.
0x0406
server
Occupancy Sensing
Mainly used based on PIR sensor
0x0500
server
IAS Zone
Mainly used based on PIR sensor
1.2.1 Basic -0x0000 (Server)
Attributes Supported:
Attribute Type Description
0x0000
INT8U,
read-only,
ZCLVersion
0x03
0x0001
INT8U,
read-only,
ApplicationVersion
This is the software version number of the application
0x0002
INT8U,
read-only,
StackVersion