Specifications

– 16 –
TROUBLESHOOTING GUIDE
common terminal
(5)
(1)
tester
resistance
terminal block
CHECK A FOLLOWING STEPS
fig. 3Voltage of IN fan motor on the IN PCB (main)
fig. 1Voltage of OUT fan motor on the OUT PCB( main)
fig.4Resistance of 4-way valve coil
fig. 5Resistance of IN louver motor
Normal:1.5k1
Take off the connector and check the Resistance of 4-way valve coil.
Normal:360 3901
Take off the connector and check the resistance between
the common terminal and each terminal.
Check the IN PCB(main)
Measure the voltage between the connector pins in the back
of IN PCB(main).
attention
electric shock
Normal:110V 230V
fig. 2Continuity of current fuse on the OUT PCB(filter)
yellow
blue
red
tester
voltage
IN fan motor
connector
4-way valve coil
1.5kΩ
W
R
B
GR
10
AC230V
Measure the voltage between white and black in the connector.
18
AC230V
W
BR
B
While the operation switch is turned on, the function of control board
is considered normal as long as the voltage difference shows AC230V
when the voltage is measured between the white and the black terminals,
and between the black and the grey terminals respectively.
B
BR
W
: BLACK
: BROWN
: WHITE
B
GR
R
W
: BLACK
:GRAY
:RED
: WHITE