Technical data

Sleep Timer features
During Cooling Operation
T
he setting temperature rises 0.6°C after 30 minutes of Sleep Timer ON, and rises
0
.6°C again after 30 minutes of the first temperature rise.
During Heating Operation
The setting temperature drops 0.6°C after 30 minutes of Sleep Timer ON, and
d
rops 0.6°C again after 30 minutes of the first temperature drop.
Emergency and test operation
Emergency Operation
The emergency operation is needed only when the remote control can not be used.
When you press the Emergency Operation Switch, you will hear a beep and the emergency operation
starts.
Emergency operation is preset for the following two modes, only based on the temperature of the
room at the time of operation.
Test operation
Same switch as used in Emergency operation.
Test operation is needed in special occasion when you need to test the “cooling operation” even with
the room temperature below 16°C, therefore it is not for the normal operation at all.
Press the Emergency operation switch and hear the beep once, then keep on pressing the switch for
more than 5 seconds but no more than 10 seconds. After the first 5 seconds you will hear two beeps
then release the switch and you will have the Test Operation Mode.
The Test Operation Mode will run the air conditioner at “cooling” with air flow speed at “Hi” for 30
minutes and stops automatically.
Termination of emergency or test operation
You can terminate the operation when you hear a beep by either pressing the switch once more, or by
operating through remote control.
When you operate through remote control, is automatically get back to just normal operation mode by
remote control.
G
NOTE
Emergency operation at the temperature between above 23°C and below 26°C just switch the
machine in operation in “cooling mode” without actually “cooling”. It is not possible to operate
in “Dry” mode.
Temperature
Operation
mode
Designated
temperature
Timer mode Air flow
Above 23°C Cooling 26°C Continuous Automatic
Below 23°
C
Heating 23°
C
Continuous Automatic
4
32