Technical data
4
11
Heating Operation
1. Press the ON/OFF button
2. Set the operation mode to Heating , by pressing the operation mode button.
3. Adjust the setting temperature by pressing the temperature setting buttons.
Temperature setting range:16~30°C by 1°C step.
4. Adjust the fan speed by pressing the fan speed button. When the MODE is
set at “AUTO”, the fan speed changes automatically.
5. Press the ON/OFF button again.The system will retain the previous setting
conditions until next operation.
G
NOTE!
• Unless the heat exchanger gets warm enough, the air will not flow out to prevent cold air.
• Even if you press the ON button right after the operation stop, the air conditioner will not
start operation for approx. 3 min. in order to protect the compressor. The operation will start
automatically after 3 min. of waiting.
• During the heating operation, the outdoor unit may frost and heating capacity may
deteriorate. In this case, the unit stops its heating operation and conducts defrosting operation
automatically
. During the defr
osting operation, the fans of the indoor and outdoor units stop.
• If it is difficult to warm the room because of low outdoor temperature, use additional heating
equipment.
* For Dual and Triple models only
Only one operation mode should be selected at a time for all the indoor units. (Different
modes can not be concurrently selected for the indoor units.) If one or two indoor units are
alr
eady operating in a cer
tain mode, another mode can not be selected for the other indoor
units. A warning beep will sound, and the unit will not function. When this happens, select the
same mode as the other operating units.
G
N
OTE!
• Even if you press the ON button right after the operation stop, the air conditioner will not
start operation for approx. 3 min. in order to protect the compressor. The operation will start
a
utomatically after 3 min. of waiting.
• If the unit operates cooling and dry for a long time in high humidity (i.e., windows and doors
are opened), dew and water droplets may form on the indoor unit.
• If you set a low temperature for dry operation, you may feel the air flow is cold.
• During dry mode operation, the system performs the cooling operation until the room
t
emperature reaches 1~2°C (1.8~3.6°F) above the setting temperature. Then it continues dry
mode operation intermittently with fan speed at “LO”, regardless of the designated speed.
• During dry operation, the indoor unit stops operating for 3 minutes when the room
temperature reaches the setting temperature.
* For Dual and Triple models only
Only one operation mode should be selected at a time for all the indoor units. (Different
modes can not be concurrently selected for the indoor units.) If one or two indoor units are
already operating in a certain mode, another mode can not be selected for the other indoor
units. A warning beep will sound, and the unit will not function.When this happens, select the
same mode as the other operating units.