Specifications
4
69
K TECHNICAL SPECIFICATIONS
Use indicatively, subject to change.
* Conform EN 14511-2007, based on single duct use
** Moisture removal at 27°C, 60% RH
*** See chapter B
Environmental information: This equipment contains fluorinated greenhouse
gases covered by the Kyoto Protocol. It should only be serviced or dismantled by
professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the table
above. Do not vent R410A into atmosphere: R410A, is a fluorinated greenhouse
gas with a Global Warming Potential (GWP) = 1975.
Waste electrical products should not be disposed with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
Model
P 227 PH 227 P 229 PH 233
Cooling capacity* W 2700 2700 2900 3300
A A A B
2,62 2,62 2,7 2,5
Heating capacity*
W2700 3150
Heating performance
CC
COP*
2,61 2,61
Power consumption
kW 1,03 1,03 1,07 1,32
Current nom.
A 5 5 4,2 4,8
Mains V/Hz/Ph
230 / 50 / 1 230 / 50 / 1 230 / 50 / 1 230 / 50 / 1
Air delivery max.
m
3
/h
300 300 300 280
Dehumidification max. **
L/24h 26 26 35 40
For rooms up to
m
3
65- 90 65 - 90 70 - 95 80 - 105
rotary rotary rotary rotary
Refrigerant
type/gr R-410A / 650 R-410A / 650 R-410A / 560 R-410A / 630
Thermostatic range
°C 16 - 32 16 - 27 16 - 32 16 - 27
3 3 3 3
Max. sound pressure level
dB (A) 40-51 40-51 37-52 37-49
Dimensions (w x h x d)
mm 436 x 745 x 390 436 x 745 x 390 440 x 745 x 390 440 x 745 x 390
Weight
kg 30
31 29 33
IP 20 IP 20 IP 20 IP 20
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Sterionizer
TM
+ & - Ions / sec
1,0 * 10
9
1,0 * 10
9
1,0 * 10
9
1,0 * 10
9
EVS*** Yes Yes Yes Yes
250V, T3,15A 250V, T3,15A 250V, T3,15A 250V, T3,15A
Fuse rating
EE Class
EER*
Compressor type
Fan speed positions
Remote control
Bacterio-static 3M
TM
HAF filter + screen filter
Active carbon filter
Unit protection
man_Px2xx_1.qxd:man_P122-125.qxd5 22-12-10 15:56 Page 69










