1. Fit the Installation Plate
1. Fit the installation plate a horizontally on structural parts of the wall with spaces around the installa-
tion plate.
2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert
Clip anchor
b for appropriate mounting screws c.
3
. Fit the installation plate
a o
n the wall with eight (8) type “A” screws
c.
G
NOTE
Fit the Installation Plate and drill holes in the wall according to the wall structure and
corresponding mounting points on the installation plate. (Dimensions are in “mm” unless
otherwise stated)
4
56
150 mm or more to ceiling
I
ndoor unit outline
Installation plate
Over 12 cm from the wall
Over 12 cm
f
rom the wall
L
eft rear side refrigerant
pipe hole Ø65
Right rear side
refrigerant pipe
h
ole Ø65
Fig. 5
W
all
Indoor
Outdoor
Fig. 6
A:780 (< 4.6 kW model)
5 - 7 mm
per 100 mm
Installation plate
920 (4.6 kW model < 6.1 kW)
1
50 mm or more to ceiling
Installation plate
Indoor unit outline
O
ver 12 cm from the wall
Over 12 cm from the wall
Right rear side
r
efrigerant pipe
hole Ø65
Left r
ear side r
efrigerant
p
ipe hole Ø65
1036 6.1 kW model