Service manual
4
55
INDOOR UNIT INSTALLATION
G
ATTENTION
•
This illustration is for explanation and indication purposes only. The illustrations may be
different from the airconditioner you purchased.
• Copper lines must be insulated independently from each other.
G
CAUTION
• Ensure that the space around the left and right of the indoor unit is more than 12cm.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
• Use a stud finder to locate studs to prevent unnecessary damage to the wall.
A minimum pipe run of 3 metres is required to minimise vibration & excessive noise.
• The indoor unit should be installed on the wall at a height of 2.3 metres or more from the
floor.
• At least two of the directions A, B and C should be free from obstructions.
8
9
7
C
B
A
6
2
3
1
1
5 cm or more
12 cm or mor
e
12 cm
or
m
ore
Air filter
LEFT
3
0
cm or mor
e
Air outlet
60 cm above
F
RONT
200 cm or more
BACK
30 cm or more
RIGHT
60 cm or mor
e
Loop the
c
onnective cable
Remote Controller
Mounting screw B
S
T2.9x10-C-H
Remote controller holder
Correct orientation
of Installation Plate
Fig. 4