INSTALLATION OF INDOOR AND OUTDOOR UNITS
Read completely, then follow step by step.
Indoor unit
• Do not expose the indoor unit to heat or steam.
• Select a place where there are no obstacles in front or around the unit.
• Make sure that condensation drainage can be conveniently routed away continuously going down-
wards.
• Do not install near a doorway.
• Ensure that the space on the left and right of the unit is more than 12cm.
• Use a stud finder to locate studs to prevent unnecessary damage to the wall.
• A minimum pipe run of 3 metres is required to minimise vibration & excessive noise.
• The indoor unit should be installed on the wall at a height of 2.3 metres or more from the floor.
• The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
• Any variations in pipe length will/may require adjustment to refrigerant charge.
Outdoor unit
• If an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that
heat radiation fr
om the condenser is not r
estricted.
G
C
AUTIONS
Do not install the unit in a place where a flammable gas leaks.
• If gas leaks and accumulates in the area surrounding the unit, it could cause an explosion.
Perform the drainage/piping work according to the installation instruction.
• If there is a defect in the drainage/piping work, water could leak from the unit and household
goods could get wet and be damaged.
More than 15 cm.
More than 12 cm.
M
ore than 12 cm.
2.3 m or more
LEFT
More than 30 cm.
BACK
More than 30 cm.
RIGHT
More than 60 cm.
FRONT
More than 200 cm.