Specifications
4
91
B THE INSTALLATION
The airconditioner is mobile and can easily be moved to a different location.
While moving the device, take account of the following:
Ensure that the device is upright and on a flat surface.
Place the filters supplied in the filter holder (see chapter D).
Do not use the device in the bathroom, shower or any other damp
environment.
Leave a gap of at least 50 cm around the device in order to ensure effective
air circulation.
Open the air outlet
T on the top of the airconditioner.
Insert both ends of the air hose
J into the hose connectors N and twist them
to the right onto the hose(s). Attach the hose adapter
Q to one end.
Attach the hose connector
N to air outlet D at the back of the unit. Lead the
hose adapter
Q outside and close the gap with the foam components
supplied. These may have to be cut to size.
7
6
5
4
3
2
1
G
ATTENTION!
• Your airconditioner must be standing upright for at least two hours
before use.
• Ensure that the air outlet on the front of the unit
T is always open
when the device is in use. The device may be damaged if this is closed
while the device is in use. The user is responsible for the correct use of
the airconditioner.
G
ATTENTION!
• Never use the device with a damaged cable or plug. Never allow the
cable to be pinched off or come into contact with sharp edges.
• Never seal the room in which the device is to be used completely
airtight (also not when using two air hoses). This will prevent the
o
ccurrence of underpressure in this room. Underpressure can disrupt
the safe operation of geysers, extractor fans, ovens, etc.
• Failure to follow the instructions may lead to invalidation of the
guarantee on the device.
• Always lift the device with two people.
man_uk_P7xx.qxd 08-11-2006 15:21 Pagina 91