man_Px2xx_1.
man_Px2xx_1.qxd 2 19-05-2008 11:52 Pagina 2 ALLGEMEINE SICHERHEIT Aus Sicherheitsgründen bitten wir Sie, die Bedienungsanleitung vor Inbetriebnahme sorgfältig zu lesen! Personen, die mit der Bedienungsanleitung nicht vertraut sind, dürfen das Gerät nicht bedienen. A. B. C. D. E. F. 6 Kein beschädigtes Kabel verwenden. Kabel nicht zusammendrücken oder knicken. Unbedingt waagerecht aufstellen. Nicht vor geöffneten Fenstern aufstellen. Nicht mit Chemikalien in Kontakt bringen.
man_Px2xx_1.qxd 19-05-2008 11:52 > Pagina 3 SICUREZZA Per motivi di sicurezza, si raccomanda di leggere attentamente il manuale prima di utilizzare l’apparecchio. Le persone che non conoscono il funzionamento del climatizzatore non devono usarlo. Si raccomanda di riporre il manuale in un luogo sicuro per future referenze. A. Non usare il cavo, se danneggiato. G. Non immergerlo nell’acqua. B. Non bloccare o piegare il cavo. H. Non versare liquidi sull’apparecchio. C.
man_Px2xx_1.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 55 Dear Sir, Madam, Congratulations on the purchase of your Zibro air conditioner. This air conditioner has five functions in addition to cooling the air, namely heating (for PH 227 only), air dehumidification, circulation and filtration as well as purification of air by it’s unique sterionizer bi-polar ionisation. The mobile air conditioner is extremely easy to operate and move.
man_Px2xx_1.qxd 19-05-2008 11:53 A Pagina 56 G SAFETY REGULATIONS IMPORTANT • The installation must be completely in accordance with local regulations, ordinances and standards. • The device is suitable exclusively for use in dry places, indoors. • Check the mains voltage. This device is suitable exclusively for earthed sockets – connection voltage 230 Volt/ 50 Hz. • The device MUST always have an earthed connection. You may absolutely not connect the device if the power supply is not earthed.
man_Px2xx_1.qxd 19-05-2008 11:53 B Pagina 57 G ATTENTION! G WARNING • Never use the device with a damaged cable or plug. Never allow the cable to be pinched off or come into contact with sharp edges. • Never seal the room in which the device is to be used completely airtight (also not when using two air hoses). This will prevent the occurrence of underpressure in this room. Negative pressure can disrupt the safe operation of geysers, extractor fans, ovens, etc.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 58 P227 and PH227 are fitted with the EVS (Effective Ventilation System) as standard. G The second hose 7 must be attached in order to utilise this option. Attach the hose connectors K and the hose adapter as described above. ATTENTION! The device can be used with 1 or with 2 hoses. If the device is used with 2 hoses, it may fall into a different Energy Efficiency Class. Refer to the technical specifications in this manual.
man_Px2xx_1.qxd 19-05-2008 11:53 C Pagina 59 G OPERATION / REMOTE CONTROL ATTENTION! • Avoid the remote control from getting wet. Remove it from the unit when condensation can occur.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 60 PLACING BATTERIES IN THE REMOTE CONTROL Remove the battery cover by pressing the lips in and then pulling the cover toward you. Place the new batteries as indicated (pay attention to the plus- (+) G and minus poles (-). Now replace the battery cover. NOTE! Use 2 AAA (1.5 Volt) batteries. Do not use rechargeable batteries. Replace batteries with new batteries of the same type when the display becomes fuzzy or the signal deteriorates.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 61 Automatic regulation of ventilator speed High Average Low • The temperature can be set between 16°C and 32°C (PH227: 16°C - 27°C) by pressing the G and H buttons. The display on the remote control shows the G set temperature. Whether the desired temperature can actually be reached depends on the ambient conditions. The room temperature remaining above the set temperature is normal.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 62 CIRCULATING Fan mode (green) When the air circulation mode is switched on, the transparent 1/2 ring around the button on the front of the device B emits GREEN light. In this mode, the air is circulated and filtered but not cooled, dehumidified or heated.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 63 You can delete the set timer function by pressing the button on the remote control. When the set time is at “00”, the timer is switched off. When the Timer function has been set the blue light in the button on the front of the device will switch on. 5 ADJUSTING THE CLOCK • Press Timer/Clock button for 3 seconds. Change the time by pressing the G and H -button.
man_Px2xx_1.qxd 19-05-2008 11:53 Pagina 64 new filter recommended change of filter 3 If it has become dusty, the activated carbon filter can be cleaned with a vacuum cleaner, but it must be replaced simultaneously with the Bacteriostatic 3MTM HAF filter. Excessive dust, building work, pets, the presence of smoke and frequent use of the device affect the lifespan of the Bacterio-static 3MTM HAF filter.
man_Px2xx_1.qxd 19-05-2008 11:53 E Pagina 65 EMPTYING THE WATER RESERVOIR In extreme circumstances it may be necessary to empty the internal water reservoir. When the water reservoir is full, the transparent 1/2 - ring around the button on the front of the device B flashes RED. To empty the water reservoir, take the following action: 1 Do not move the device. This may cause water leakage. 2 First switch the device off and remove the plug from the socket.
man_Px2xx_1.qxd 19-05-2008 11:53 G Pagina 66 G MAINTENANCE ATTENTION! First switch the device off and pull the plug out of the socket before you clean the device or filter or when you replace the filters. Use a soft, damp cloth for the regular cleaning of the exterior of the device. Never G use aggressive cleaning agents, solvents, benzene or abrasives. Refer to chapter D “Air Filter” for filter maintenance. H NOTE! Never use the device without the mesh filter.
man_Px2xx_1.qxd 19-05-2008 11:53 I Pagina 67 PROBLEMS AND SOLUTIONS Problem Cause Solution The device does not work and the transparent 1/2 The internal water ring around the button on reservoir is full. the front of the device flashes RED. Empty the internal water reservoir (see chapter E). The device does not work and the left hand side of the transparent 1/2 - ring around the button on the front of the device flashes BLUE. The room temperature sensor is defective. Consult your dealer.
man_Px2xx_1.qxd 19-05-2008 11:53 J Pagina 68 GUARANTEE CONDITIONS We provide a 24-month warranty on the airconditioner from the date of purchase. All material and production faults will be repaired free of charge within this period. The following rules apply: 1. We expressly reject all other claims for damage compensation, including consequent damage. 2. Repairs or replacements carried out during the guarantee period do not result in an extension of the guarantee. 3.
man_Px2xx_1.qxd 19-05-2008 11:53 K Pagina 69 TECHNICAL SPECIFICATIONS Use indicatively, subject to change. Model Cooling capacity* W P 227 PH 227 2700 2700 A A 2.62 2.62 EE Class EER* Heating capacity* W 2700 Heating performance C COP* 2.61 Power consumption kW 1.03 1.03 A 5 5 V/Hz/Ph 230 / 50 / 1 230 / 50 / 1 Air delivery max. m3 /h 300 300 Dehumidification max.
19-05-2008 11:53 Pagina 120 4 UNITED KINGDOM Scott Brothers Ltd. The Old Barn, Holly House Estate Cranage, Middlewich, CW10 9LT UK tel.: +44 1606 837787 fax: +44 1606 837757 email: sales@scottmail.co.uk e BELGIË PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel: +32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro.com > ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO (FI) tel: +39 571 628 500 fax: +39 571 628 504 email: pvgitaly@zibro.