5. Counter/Timers
40
The six programmable operating modes are summarized in the "Counter/Timer
Operating Modes" table following.
Counter/Timer Operating Modes
Mode Counter/Timer Output Operation
0 Transitions after programmed count expires
Gate tied high to enable counting
1 Transitions after programmed count expires
Gate tied high to enable counting
2 Periodic single pulse after programmed count expires
Gate tied high to enable counting
3 Square wave with frequency equal to programmed count
Gate tied high to enable counting
4 Single pulse after programmed count expires
Gate tied high to enable counting
5 Single pulse after programmed count expires
Gate tied high to enable counting