User manual

12. Watchdog Timer
102
Watchdog Timer Counter Registers
The Watchdog Timer Counter registers hold the current value of the down counter.
Application software reads these registers to determine the current count value. A
reload operation automatically transfers the contents of the Watchdog Reload registers
to the Watchdog Timer registers.
Register:
Access:
Address:
765432
10
15 14 13
12
11
10
9
8
WDT Count High
F4C4h
Read
WC31
WC30 WC29
WC28 WC27
WC26
WC25 WC24
WC31
WC23
WC22 WC21 WC20 WC19 WC18 WC17 WC16
Current WDT Count High
Register:
Access:
Address:
765432
10
15 14 13
12
11
10
9
8
WC31
WDT Count Low
F4C6h
Read
Current WDT Count Low
WC15 WC14
WC13 WC12 WC11 WC10 WC9 WC8
WC7 WC6
WC5
WC4 WC3
WC2 WC1
WC0
Watchdog Timer Counter Registers