Specifications

Getting Started
SYSTEM REQUIREMENTS
The ZT 8832 is designed for use with or without an STD bus
backplane. For STD bus applications, the ZT 8832 is mechanically
and electrically compatible with Version 1.1 of the STD 32 Bus
Specification and Designer’s Guide.
Vertical mounting is recommended in applications not using a fan.
Horizontal mounting requires a minimum air flow of 30 cubic
feet/min. passing over the surface of the board.
Refer to Appendix B for additional specifications.
ZT 8832 Requir
ements
The ZT 8832 requires +5 VDC ±5% at 1.5 A maximum, +12 VDC
±10% at 0.10 A maximum, and -12 VDC ±10% at 0.10 A maximum.
The ambient temperature range must be maintained between 0 and
+65˚ Celsius to guarantee proper operation and to avoid damage.
Relative humidity must be less than 95% at 40˚ Celsius, non-
condensing.
ZT 88CT32 Requir
ements
The ZT 88CT32 requires +5 VDC ±5% at 0.5 A maximum, +12 VDC
±10% at 0.10 A maximum, and -12 VDC ±10% at 0.10 A maximum.
The ambient temperature range must be maintained between -40˚ and
+85˚ Celsius to guarantee proper operation and to avoid damage.
Relative humidity must be less than 95% at 40˚ Celsius, non-
condensing.
2-3