Specifications
4
Package Contents
Unpack and Inspect the network extender. If there is any visible damage, do not attempt
to connect the device. Contact your sales or service provider.
Powering Up the Network Extender
The DC power terminal block on the network extender has five terminals: two positive,
two negative, and one ground. Only one positive terminal and one negative terminal pair
need be connected for operational purposes. The second positive and negative terminal
pair may be connected to a backup DC power supply for redundancy. The ground
terminal must be connected regardlessly. DO NOT OPERATE THE NETWORK
EXTENDER WITHOUT A GROUND CONNECTION.
Procedure
1. Loosen all screws at the top of the power terminal strip.
2. Insert your ground wire in the center terminal and tighten the screw.
3. Insert your positive and negative leads into the left or right + and – pair of terminals,
taking care to match polarity. Tighten the screws for those terminals.
4. Repeat Step 3 for the free pair of power terminals if you have a redundant power
supply.
04-17607
1
2
3
4
10/100 Ethernet Connections
48V .45A
MAX