Instruction manual

9
LED Indicators
Table 3. LEDs (1 of 2)
LED STATE INDICATION
ADDITIONAL
INFORMATION
Power Solid Green SNE2000G is
operational
If the Power LED is not
illuminated, it is likely the
SNE2000G is NOT receiving
power, in which case none of the
LEDs will be illuminated.
Available
SHDSL
Connection
Pulsing
Green*
SHDSL
connection is
established and
active
Traffic is flowing.
Solid Green Problematic
SHDSL
connection
A connection exists but there is
indication of a problem with the
SHDSL line.
No
Illumination
No SHDSL
connection
Ethernet
Collision
No
Illumination
Standard Either there is no traffic or traffic is
flowing without any collisions. If
there is no Ethernet connection,
the Ethernet Collision LED will
remain unlit by default.
An SNE2000G in Full Duplex
mode does not have collisions; the
Ethernet Collision LED is only
applicable in Half Duplex mode.
Flashing
Red
Packet collision(s) The Ethernet packet(s) will
automatically be retransmitted.
Solid Red Warning There is a potential traffic problem
over the Ethernet segment.
Ethernet Rx Flashing
Amber
Ethernet activity The SNE2000G is receiving data
from the Ethernet network.
Solid Amber Heavy Rx traffic The SNE2000G is receiving large
amounts of data from the Ethernet
network. A solid amber Ethernet
Rx LED can also signify a lost
SHDSL connection.
No
Illumination
No activity Either there is no Ethernet link or a
link exists but there is no activity.