Specifications

3-16 System Operation
Model No.
Running Head
Cross-Connecting (XCON) System Configuration and Operation
3.8 Cross-Connecting (XCON)
From the System Main Screen, you can access a Cross-Connect Screen by pressing “x
(Xcon) that lets you cross-connect WAN time slots between T1 links. Refer to the
Cross-Connecting WAN Time Slots section later in this manual.
3.9 System Level Maintenance
You can also go from the System Main Screen to a Test and Debug Screen, by pressing y
(sYstem) which allows you to perform system-level maintenance operations. You can back up
the system configuration onto an external computer after saving and subsequently editing it,
and (if necessary) you can restore that configuration to the system (refer to the backup and
restore section later in this chapter). You also can erase the system configuration and restart
the system with a single “zip” command.
3.9.1 Test, Debug, Backup & Restore
Advanced configuration and diagnostics are available through the use of the sYs (sYstem)
command from the System Main Screen. Pressing “y” brings up the Test and Debug screen
shown in Figure 3-12.
Figure 3-12.System Test and Debug Screen