Specifications
3-10 System Operation
Model No.
Running Head
Reinitializing the System System Configuration and Operation
3.6 Reinitializing the System
The system stores information about its currently installed ports, the port configuration option
settings, WAN connections, passwords, and other data in nonvolatile memory (NVRAM).
When you change any settings on the port types, the NVRAM remembers the previous port
settings.
Restart capability is available on the IMACs-200. If the user desires to restart the IMACS-200,
capability is available on the main login screen with the Oos command. This command will
restart the box, as shown in Figure 3-6. preserving all provisioned data.
Figure 3-6.Rebooting the IMACS-200
If you have redeployed the IMACS-200, or otherwise desire to re-initialize the unit to the
default settings, you can āzipā it, causing it to be reprogrammed. From the main login screen,
enter āYā to go to sYstem. A screen such as what is seen in Figure 3-7 appears
.
Figure 3-7.System Screen - Test and Debug.