Specifications
System Standards and Specifications A-5
A.3 Chassis Standards
A.3.1 Dimensions
Note: Weight is weight of empty chassis with backplanes and power distribution channel.
A.3.2 Chassis Power
A.3.3 Environment
A.3.3.1 Ambient Temperature and Humidity
Ambient temperature and humidity as per GR-63-CORE R4-6 and R4-7.
Chassis Description
Model
Number
Height Width Depth Weight
in cm in cm in cm lb. kg
Chassis with Installation Kit,
Dual-Powered, Steel Chassis,
CE Marked
IMACS-200 3.47 8.8 9.48 24.1 17.31 44.0
Chassis Description
Model
Number
AC Power (50-60 Hz) DC Power
Power
Consumption
110 VAC 220 VAC -48 VDC -125 VDC Watts
Chassis with Installation Kit,
Power-Enhanced, Steel
Chassis, CE Marked
IMACS-
200
115 VAC
104 to 135
VA C
175 VAC
to 264
VAC
-40 VDC
to -60
VDC
125 (typical)
500 W
(maximum)
Temperature
o
C /
o
F Humidity
Operate Short Term Storage Operate Short Term
0 to 50
o
C
32 to 122
o
F
-5 to 50
o
C
23 to 122
o
F
-20 to 80
o
C
-4 to 176
o
F
50 to 95% relative
humidity, non
condensing
5 - 90 (not to exceed
0.024 kb H
2
O/kg dry
air)
Rate of temperature change
30
o
C/hr (54
o
F/hr)