Specifications
E&M Ports 7-3
Table 7-1. Main Screen Actions
Table 7-2, “Main Screen Option Settings and Defaults,” on page 7-3 summarizes the
configuration settings for the E&M port, along with the available and factory-default option
settings. The parameters and settings are also described in the following paragraphs.
Table 7-2. Main Screen Option Settings and Defaults
Notes:
1. Choosing wan allows you to choose a WAN port (w1-1 through w1-4). See the WAN
paragraph that follows.
2. The extended setting range for the IMACS-200 E&M port is from -16.3 to +7.5 dB.
STATE
The State setting determines whether the port is active or inactive. An inactive port does not
occupy a time slot on a WAN link. Set this field to stdby (standby) for ports that will not be
used or that are not yet configured. Or, set it to actv (active) for ports that are ready for use.
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Updates certain time-related information fields that are not automatically
updated (i.e., test status).
Copy Copies the contents of the current column to the next column. Useful if you
change a lot of entries in one column and wants to repeat those changes in
subsequent columns.
Main Returns to the System Main Screen. If you make changes to settings and do
not save them, you will be prompted to save or lose changes.
Parameter User Options Notes Default
STATE stdby actv stdby
WAN/SRV none wan 1 none
TS 01-24 01
MODE to to
Rx TLP -16.3 dB to +7.5 dB 0
Tx TLP -16.3 dB to +7.5 dB 2 0
CODING u-law a-law u-law
LB off dgtl anlg off
PATTRN none D-mW none