Specifications
Power Source
AC: 120 Volts @ 2.0 amps / 240 Volts @ 1 amp, 50/60 Hz
DC: +24 Volts @ 3.0 amps / -48 Volts @ 1.5 amps
Additionally, the DC source must provide a means of disconnecting power from the supply,
and the supply voltage must be provided from an isolated source complying with SELV
requirements of EN60950.
Fusing
To avoid a fire hazard, use only fuses with the specified type and rating with the system.
Panel and Cover Removal
Qualified service technicians should only attempt the removal of covers and panels.
Notice!
Never attempt to operate the equipment with the power panel fasteners
removed. Also do not remove power panel covers without first disconnecting
the input power.
Regulatory Compliance Information
FCC Part 68 Information
This equipment complies with Part 68 of the FCC rules.
The equipment has FCC Registration Number 1H5SNG-73866-DD-E. This equipment uses
the following USOC jacks: RJ11C, RJ21X, RJ2EX, RJ2FX, RJ2GX and RJ2HX.
The REN is used to determine the quantity of devices that may be connected to the telephone
line. Excessive RENs on the telephone line should not exceed five (5.0). To be certain of the
number of devices that may be connected to the line, as determined by the total RENs, contact
the telephone company to determine the maximum RENs for the calling area.