Specifications

3-30 Reference Guide
Model No.
Running Head
Assigning Time Slots to a User Card System Configuration and Operation
2. Select the WAN port to which you want to assign the HSU port. In Figure 3-17, this
port is
W1-1
(for WAN 1, port
1).
Select the TS table. All time slots of the selected WAN port appear at the bottom of the
screen. These are 1 to 24 for a T1 port, or 1 to 31 for an E1 port
Place an
X
under each desired time slot, using the space bar to either select or de-select
a time slot. Use the right arrow key to move to the next time slot (TS) for selection. Then,
press <Enter>.
In Figure 3-17, the HSU port is assigned eight time slots (9 to 16).
4. Change the STATE of the port from
stdby
to
actv
.
5. Press
s
to save your settings.
Figure 3-17. Typical HSU Card Time Slot Assignments
Node_1 | U1 HSU-366x2 Rev A04-0 Ser 01103 | 12-31-99 14:33
1 2
STATE stdby stdby
WAN/SERVER w1-1 w1-1
TS table table
RATE 64K 64K
Tx CLOCK int int
CLOCK PLRTY norm norm
DATA PLRTY norm norm
CTS perm perm
CTS DELAY 0 0
LOCAL LB off off
LB GEN MODE dds dds
LB GEN off off
LB DET w/to w/to
ISDN CONN no no
ERR off off
1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
x x x x x x x x
Save | Undo | Refresh | Copy | Test | Dial | Perf | Main