Specifications
Reference Guide B-5
Combined ADPCM rate must equal 64K.
You cannot assign a 40 kbps and a 32 kbps channel to the same ADPCM 64 kbps engine. The
only valid combinations are 40 kbps + 24 kbps, 32 kbps + 32 kbps, and 24 kbps + 40 kbps.
Command rejected. Switch in progress.
The command was not executed because a redundancy switch is in progress.
Config. changes must be made from primary WAN.
You cannot make configuration changes to a redundant WAN port. This is allowed only on
primary WAN ports.
CONG stat is not available for FRAD port.
Frame relay packet congestion data is not available for this FRAD port.
Cumulative bandwidth exceeds 115.2K.
You cannot assign more than 115.2 kbps of aggregate bandwidth to an SRU card. Be sure the
sum-total rate of all card ports does not exceed 115.2 kbps.
Current CPU does not support redundancy.
The selected CPU card does not support redundancy. If the system has two CPUs, be sure they
are both 8803s.
Dialing is not available with Alarm Card.
If an External Alarm card is present in the system, you cannot use dial triggers for the HSU
card. Remove the External Alarm card first.
ds0-n available only with 64K rate.
You cannot generate a DS0 time slot (ds0-n) loopback on an OCU-DP port with a data rate of
less than 64 kbps. This is possible only on ports operating at 64 kbps and higher.
Duplicate prt report element.
You have asked the Print Alarms option to print the smae element twice.