Specifications

Reference Guide B-3
Cannot define any more PVC connections.
The maximum number of PVC connections has been reached.
Cannot define any more XCON circuits.
The maximum number of cross-connect circuits is 99.
Can NOT delete circuit while test is active.
You must end the test in progress before deleting the circuit.
Cannot do it in Viewer mode.
You are logged in under the Viewer password, but that level of access does not allow you to
perform the desired operation. Log out of the system, log back in under the Operator or
Manager password, and repeat the command. Or, perform an operation that is permitted by the
Viewer access level.
Cannot exceed 32 TSs for ports 1-32 or 33-64.
Each set of 32 ports can have one time slot (total of 32 time slots).
Cannot have REMOTE and LOCAL loopbacks.
You cannot place the card port in both a local loopback and a remote loopback simultaneously.
Cannot insert errors without BERT running.
You must start BERT testing before inserting bit errors.
Cannot switch non-compatible WANs.
The current WAN card arrangement does not support redundant WAN switching.
Cannot talk to NTU while BERT is running.
You must stop the BERT test before accessing the NTU.