Specifications
A-2 Reference Guide
Model No.
Running Head
Table A-3. FCC Registration Information - Part 3
A.2 UK Requirements
Table A-4. Minimum Creepage and Clearance Parameters.
A.3 System Requirements
Table A-5. System Electrical and Environmental Requirements for (front loading chassis
power supply on side, / power supply on top, and two-sided chassis).
Reg.
Digital
Interfaces
Model # SOC
Network
USOC
Canadian
Jacks
Reg. 04DU9-BN WAN SINGLE, WAN DUAL* 6.0Y RJ48 CA81A
Reg. 04DU9-DN WAN SINGLE, WAN DUAL* 6.0Y RJ48 CA81A
Reg. 04DU9-1KN WAN SINGLE, WAN DUAL* 6.0Y RJ48 CA81A
Reg. 04DU9-1SN WAN SINGLE, WAN DUAL* 6.0Y RJ48 CA81A
Reg. 04DU9-1ZN WAN SINGLE, WAN DUAL* 6.0Y RJ48 CA81A
Reg. 04DU9-BN WAN SINGLE, WAN DUAL** 6.0P N/A ---
Reg. 04DU9-DN WAN SINGLE, WAN DUAL** 6.0P N/A ---
Reg. 04DU9-1KN WAN SINGLE, WAN DUAL** 6.0P N/A ---
Reg. 04DU9-1SN WAN SINGLE, WAN DUAL** 6.0P N/A ---
M 04DU5-24 OCU-DPx2 6.0F RJ48 CA81A
M 04DU5-48 OCU-DPx2 6.0F RJ48 CA81A
M 04DU5-56 OCU-DPx2 6.0F RJ48 CA81A
M 04DU5-96 OCU-DPx2 6.0F RJ48 CA81A
* with CSU module ** with DSX module
Clearance (mm) Creepage (mm)
Voltage Used or Generated By Host or Other
Cards
2.0 2.4 (3.8) Up to 50Vrms or VDC
2.6 3.0 (4.8) Up to 125Vrms or VDC
4.0 5.0 (8.0) Up to 250Vrms or VDC
4.0 6.4 (10.0) Up to 300Vrms or VDC
For a host or other expansion card fitted in the host,
using or generating voltages
greater
than 300V (rms
or DC), advice from a competent
telecommunications safety engineer must be
obtained before installation of the relevant
equipment.
Above 300Vrms or VDC