Specifications
6-42 Reference Guide
Model No.
Running Head
PARS Screen WAN Card
Figure 6-33. Typical T1 WAN PARS Screen
Table 6-15. T1 WAN PARS Screen Actions
Table 6-16. WAN Card Test Screen Options
PARS must be made aware of the time slot(s) used by Voice cards terminated on a WAN. This
applies whether the WAN is a T1 or E1. The “sIgnaling” menu option is used to do this. In
Figure 6-33, PARS has been chosen from the WAN screen menu and then signaling has been
displayed. Time slot #3 has been selected to show that it is in use by the Voice card terminated
on this WAN.
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Updates certain time-related information fields that are not automatically
updated (i.e., performance and test data).
sIgnaling Allows signaling for voice cards to be specified via a time slot map.
Main Returns to the WAN Card Main Screen. If changes are made to settings and
not saved, you will be prompted to save or abandon those changes.
Parameter User Options Notes Default
PARS MODE yes no no
Node_1 | W1 CEPT+CEPT Rev A6-2 Ser 00101 | 12-31-99 14:33
1
PARS MODE yes
0 1 2 3 4 5 6 7 8 9
1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
X
Save | Undo | Refresh | sIgnaling | Main