Specifications

Model No.
Running Head
The Interface Card is also listed in the approval documentation and provides a direct metallic
path between the CEPT module and appropriate Connector Panel.
The power required by the host and the total of all adapter cards installed within the host
environment, together with any auxiliary apparatus, shall not exceed the power specification
of the host apparatus.
The power requirements for this E1 interface are:
AC Power Supply
AC Mains:100 - 240 Vrms, 47 - 63 Hz
or
48VDC Power Supply
DC Input:35 - 60 VDC,
±
15%, 120KVA max.
It is essential that, when other option cards are introduced which use or generate a hazardous
voltage, the minimum creepages and clearances are maintained. Suitable user protection to
ensure compliance with EN 60950 should be present on the card. A hazardous voltage is one
that exceeds 42.2V peak AC or 60VDC. If you have any doubt, seek advice from a competent
installation engineer before installing other adapters into the host equipment.
The equipment must be installed such that with the exception of the connections to the host,
clearance and creepage distances shown in the table below are maintained between the card
and any other assemblies that use or generate a voltage shown in the table below. The large
distance shown in brackets applies where the local environments is subject to conductive
pollution or dry non-conductive pollution which could become conductive due to
condensation. Failure to maintain these minimum distances would invalidate the approval.
Germany
German Approval Number
The German approval number is A118 142F.
Safety Warning
SPEZIFISCHE SICHERHEITSMAßNAHMEN
DIE EINRICHTUNG IST GEMÄß DEM SICHERHEITSSTANDARD EN60950
ENTWORFEN UND HERGESTELLT WORDEN. DOCH DIE FOLGENDEN
SICHERHEITSMAßNAMEN SOLLEN EINGEHALTEN WERDEN. UM IHRE