Specifications
Reference Guide 3-71
System Configuration and Operation Checking the Time Slot Map
Figure 3-58 shows the WAN card cross-connect screen for a bus-connect system. Time slots
19-24 show all of the possible choices for pass through circuits. The values are
no
(signaling
is not passed through and neither PCM nor SIG are converted),
pcm
(signaling is not passed
through, PCM is converted, SIG is not converted),
sig-no
(signaling is passed through and
there is no PCM or SIG conversion),
sig-sig
(signaling is passed through, PCM is not
converted, SIG is converted),
sig-pcm
(signaling is passed through, PCM is converted, SIG is
not converted) and
sig-p&s
(signaling is passed through, both PCM and SIG are converted).
Figure 3-58. Signaling and Companding Options
3.17 Checking the Time Slot Map
Once you select and assign the time slots, you can view the list of DS0 connections (the time
slot map) through the WAN card Cross-Connect Screen for cross-connect systems. You can
see the results of your assignments in the time slot map as follows:
1. From the Main Screen, select the WAN card in slot W-1.
2. Type <
x
> to bring up the time slot screen (see Figure 3-59 for T1 operation).
3. Selecting <
m
> for Main will return users to the WAN card screen.
4. Selecting <
m
> for Main again will return users to the Main screen.
Node_1 | W1 CSU+CSU 8010 Rev A6-2 Ser 00101 | 12-31-99 14:33
TS XCONNECT BW CNV TS XCONNECT BW CNV
1 u2-1 voice 64k sig 13 u5-1 data 06x56k
2 u2-2 voice 64k sig 14 u5-1 data 06x56k
3 u2-3 voice 64k sig 15 u5-1 data 06x56k
4 u2-4 voice 64k sig 16 u5-1 data 06x56k
5 u2-5 voice 64k sig 17 u5-1 data 06x56k
6 u2-6 voice 64k sig 18 u5-1 data 06x56k
7 u2-7 voice 64k sig 19 w1-2 ts-19 64k no
8 u2-8 voice 64k sig 20 w1-2 ts-20 64k pcm
9 u1-2 ts-9 64k no 21 w1-2 ts-21 64k no
10 u1-2 ts-10 64k no 22 w1-2 ts-22 64k sig
11 u1-2 ts-11 64k no 23 w1-2 ts-23 64k pcm
12 u1-2 ts-12 64k no 24 w1-2 ts-24 64k p&s
Save | Undo | Refresh | sIgnaling | Main