Installation guide

OMCI based GPON zNID
60 FTTH Application Guide
1 1-4-4-1 Yes CIGG 138543368 ME 2510-config1
GEN 2510-service-plan1
4 Run the gpononu status command to verify the OMCI state is active.
zSH> gpononu status 4/4/1
ID Onu OperStatus OmciState GponOnuStatus
=== ==================== ============= ========= ====================
1 1-4-4-1 Up Active Active
5 Run the bridge show command to view the MAC address of the
connected PC.
zSH> bridge show
Type VLAN Bridge St Table Data
---------------------------------------------------------------------------------
upl Tagged 100 ethernet5-100/bridge UP S VLAN 100 default
dwn Tagged 100 1-4-4-501-gponport-100/bridge UP D 00:00:86:43:3c:e4 MAC of PC
Testing the data bridge
Verify that the user can get data on the PC:
1 Connect an ONT downlink ethernet port to a PC.
Make sure the ONT model matches the one you assigned with the Smart
OMCI web tool. This example connects a ZNID-GPON-2510 to the PC.
And also make sure the ONT downlink ethernet port number matches the
one you assigned with the Smart OMCI web tool for data service. In this
example, you can connect either ETH 1 or ETH 2 to the PC.
2 Open a command prompt on the PC and enter ipconfig to verify that you
can get an IP address from DHCP server for the PC.
3 Open an internet browser on the PC, you should be able to access the
internet now.