User`s guide
A. Configuration Options
A-32
May 2002 7990-A2-GB20-00
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for
enterpriseSpecific
events.
Disable – No enterprise-specific event traps are sent.
NOTE: Refer to
Enterprise-Specific Traps
in Appendix B,
Standards Compliance for
SNMP Traps
.
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No
linkUp
or
linkDown
SNMP traps are generated.
Up – A
linkUp
trap is generated when the unit recognizes that one of the communication
interfaces is operational.
Down – A
linkDown
trap is generated when the unit recognizes a failure in one of the
communication interfaces.
Both – Sends trap messages for detection of both
linkUp
and
linkDown
.
NOTE: Refer to
linkUp and linkDown
in Appendix B,
Standards Compliance for SNMP
Traps
.
Link Traps Interfaces
(Model 7996 only)
Possible Settings: Network, G.703, All
Default Setting: All
Determines if the SNMP
linkUp
, SNMP
linkDown
, and interface-related
enterpriseSpecific
traps are generated for the network interface, G.703 interface, or both.
Network – SNMP trap messages are generated for the network interface.
G.703 – SNMP trap messages are generated for the G.703 interface.
All – SNMP trap messages are generated for the network interface and the G.703
interface.
Table A-12. SNMP Traps Options (2 of 2)