User`s guide

A. Configuration Options
7990-A2-GB20-00 May 2002
A-15
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed so that control can be regained after a test is accidentally executed.
Enable Loopback and pattern tests end when test duration is reached.
Disable Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to
Running DSL Tests
in Chapter 7,
Testing
.
Test Duration (min)
Possible Settings: 1 120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Test Duration (min) only appears when Test Timeout is enabled.
1 120 Amount of time in minutes a test runs before terminating.
G.703 Line Termination
(Model 7996 only)
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms
Specifies which G.703 connections are being used by the unit, the 75 TX and RX
connectors or the 120 interface.
75 ohms Line impedance is set for 75 ohms; the 75 connectors are being used.
120 ohms Line impedance is set for 120 ohms; the 120 interface is being used.
Region Setting
Possible Setting: Annex B (read-only)
For an STU-C, specifies the set of unique, regional SHDSL operations parameters to be
used by the unit.
Region Setting only appears when DSL Mode is set to STU-C.
Annex B For European networks.
Table A-6. System Options (2 of 3)