User`s guide
A. Configuration Options
7990-A2-GB20-00 May 2002
A-15
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
Disable – Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to
Running DSL Tests
in Chapter 7,
Testing
.
Test Duration (min)
Possible Settings: 1 – 120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Test Duration (min) only appears when Test Timeout is enabled.
1 – 120 – Amount of time in minutes a test runs before terminating.
G.703 Line Termination
(Model 7996 only)
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms
Specifies which G.703 connections are being used by the unit, the 75 TX and RX
connectors or the 120 interface.
75 ohms – Line impedance is set for 75 ohms; the 75 connectors are being used.
120 ohms – Line impedance is set for 120 ohms; the 120 interface is being used.
Region Setting
Possible Setting: Annex B (read-only)
For an STU-C, specifies the set of unique, regional SHDSL operations parameters to be
used by the unit.
Region Setting only appears when DSL Mode is set to STU-C.
Annex B – For European networks.
Table A-6. System Options (2 of 3)
Ω
Ω
Ω
Ω