Hotwire® ReachDSL™ Modem Model 6350-A4 Installation Instructions Document Number 6350-A2-GN12-20 May 2004 Contents Software and Firmware License Agreement ................................................. 2 Package Checklist ........................................................................................ 4 Wiring and Cables You May Need (not supplied) ......................................... 4 Installing Additional Phone Filters ...............................................................
Software and Firmware License Agreement ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you. THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, OR ORAL OR WRITTEN, INCLUDING WITHOUT LIMITATION: a.
Package Checklist Verify that your package contains the following: Rea chD SL PWR ALM TST LINE TX/R X ETH ERN ET Hotwire 6350 ReachDSL Modem Power cord with power transformer DSL interface cable with RJ11 connectors Wiring and Cables You May Need (not supplied) The following standard cables and connectors can be used with this product: Standard RJ11 (or RJ14) wall jack for the DSL cabling Ethernet 8-pin straight-through or cross-over cable 4
Installing Additional Phone Filters IC E LR P L. AC T.E CE . EQ E1 SS 00 UIPMAR 29 Y 6 EN T 92 99 7 R PROD M ad e geprufte Sicherheit UCT SERV TUY in TM /N 08 P ho ne Ch in 02 a -3 Be / Fa 39 l Fu br 2se iquè 00 In Ch c. 11 ina 98 Fi lte r LI E N A phone filter is recommended to minimize background noise during a phone conversation on telephones not connected directly to the Hotwire 6350 ReachDSL Modem.
Installing the Hotwire 6350 ReachDSL Modem Place the Hotwire 6350 ReachDSL Modem on a flat surface with clearance for the rear connectors. Procedure 1. UNPLUG TELEPHONE. If a telephone is connected at RJ11 Wall Jack the RJ11 wall jack where the ReachDSL modem will be installed, unplug the telephone line from the wall jack. 2. CONNECT A TELEPHONE. (Optional – go to Step 3 if you are not connecting a telephone to the modem.
4. CONNECT TO PC OR ETHERNET HUB. Use an 8-pin Ethernet cable (crossover or straight-through) for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET. Connect to one of the following: — ETHERNET PC. Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card (NIC) installed. POWER ETHERN ET PC with Ethernet Network Interface Card – or – Ethernet Crossover Cable — Ethernet Hub.
Optional ReachDSL Modem Wall Placement The Hotwire 6350 ReachDSL Modem is designed for tabletop placement. The modem can also be mounted on a wall. To mount the modem, you will need: ❑ Two slotted-head #6 self-threading screws with plastic anchors ❑ Drill and 3/16" drill bit for the plastic anchors ❑ Screwdriver A template with the dimensions for the two screws is provided. See ReachDSL Modem Hardware Template on page 9. Procedure To mount the Hotwire 6350 ReachDSL Modem: 1.
Bottom 5.
Status LEDs When power is applied, the ReachDSL modem performs self-diagnostics and the PWR LED is on. The self-diagnostics include a power-on self-test during which all of the LEDs turn on for one second. Power – green Alarm – red Test – yellow DSL Line – green Transmit/Receive – green Ethernet Link – green PWR ALM TST LINE TX/RX ETHERNET ReachDSL 01-17003 All of the LEDs turn on and off during the power-on self-test.
Troubleshooting LED Symptom Action All LEDs are on. If LEDs remain on after ten minutes, the modem is not functional. Contact the service provider. ALM LED remains on. The power-on self-test may have failed. Unplug the unit and reapply power. If the alarm LED is still on, contact the service provider. ALM and TST LEDs are blinking. Firmware download may be in progress. If firmware download is not in progress or the LEDs continue blinking after ten minutes, contact the service provider.
To improve data transmission throughput and minimize background noise during a telephone conversation, make sure that: The Hotwire 6350 ReachDSL Modem is always powered on, even when not in use, and A Hotwire phone filter is installed on every telephone on the same line as the Hotwire 6350 ReachDSL Modem. Increasing the Number of End-User Systems A single end-user system is attached to the Hotwire 6350 ReachDSL Modem by using an Ethernet crossover cable.
Cables and Connectors Standard twisted-pair CAT3 or better cables are recommended. The LINE and PHONE interface connectors use 6-pin, non-keyed modular plugs. RJ11 or RJ14 6-pin connectors can be used. 6-Pin RJ11 Plugs Line & Phone Connectors Pin # Function 1 Not used 2 Ring 2 (optional) 3 DSL Ring 1 4 DSL Tip 1 5 Tip 2 (optional) 6 Not used Pin #6 Pin #1 98-15304a The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS.
The Ethernet interface connector uses an 8-pin, non-keyed modular plug. — To connect the DSL modem to an Ethernet hub, use the straight-through connection. Ethernet Cable 8-Pin Straight-through Connection 8-Pin Plug Pin # Function 1 10BaseT TX D+ 2 10BaseT TX D– 3 10BaseT RX D+ 4&5 Not used 6 10BaseT RX D– 7&8 Not used Pin #8 Pin #1 98-16055a –or– — To connect the DSL modem directly to a PC with an Ethernet NIC card, use an Ethernet crossover cable.
Technical Specifications for Hotwire 6350 ReachDSL Modem Item Specification* Height x Width x Depth 3.71 cm x 14.54 cm x 11.00 cm (1.46" x 5.72" x 4.33") Weight 0.20 kg (0.45 lb.) Power Class 2 Transformer normal service input voltage range Input: 100 VAC (+10%), 50 Hz; 120 VAC (+10%), 60 Hz; or 230 VAC (+10%), 50/60 Hz Output: 5 VDC nominal, minimum 0.
! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 4.
Japan – Notices This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules.
Supplier’s Declaration of Conformity Place of Issue: Paradyne Corporation 8545 126th Avenue North Largo, FL 33773-1502 USA Date of Issue: 8/17/2001 Paradyne Corporation, located at the above address, hereby certifies that the Hotwire® ReachDSL™ Model Number 6350-A4-200, bearing labeling identification number US:AW2DL03B6350-A4 complies with: the Federal Communications Commission’s (“FCC”) Rules and Regulations 47 CFR Part 68, the Administrative Council on Terminal Attachments (“ACTA”)-adopted technical
8. This equipment cannot be used on public coin service provided by the telephone company. Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.) 9. An FCC compliant telephone cord with modular plugs may be provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant.
Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.