System information

Table Of Contents
3. Commands
4821-A2-GB21-00 July 2004 3-73
Configure SNTP Interval
Configure Syslog
This command configures the Syslog threshold and rate limiting.
Configure Syslog Rate Limiting
configure sntp interval {interval}
Minimum Access Level: Administrator
The configure sntp interval command specifies the frequency that the unit should make SNTP
requests to update the date and time. The units makes a time request whenever it powers on,
then it makes periodic requests based in the interval specified.
interval The period, in hours, between SNTP requests. Valid values are 1–24. The default is 24
hours.
Example:
PDYN# configure sntp interval 12
configure syslog rate-limiting {disabled | enabled}
Minimum Access Level: Administrator
The configure syslog rate-limiting command determines whether duplicate messages are
written to the system log.
disabled – All messages (satisfying the syslog threshold setting) are written to the system log.
This is the default.
enabled – Consecutive duplicate messages are written to the system log only if they are received
more than five minutes apart.
Example:
PDYN# configure syslog rate-limiting disabled