Configure Interface DSL Profile Alarm Upstream Loss of Signal Seconds
Configure Interface DSL Profile Alarm Upstream Severely Errored Seconds
configure interface dsl-profile-alarm upstream-loss {loss} {profile_name }
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm upstream-loss command modifies the upstream
los-of-signal-seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
loss - if the number of LOSS events in a 15-minute interval meets or exceeds the selected value (0–900
seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm upstream-loss 500 adsl_alarm_profile1
configure interface dsl-profile-alarm upstream-ses {ses} {profile_name }
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm upstream-ses command modifies the upstream severely
errored seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
ses - SNMP trap is sent if the number of severely errored seconds events in a 15-minute interval meets
or exceeds the selected value (0–900 seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm upstream-ses 500 adsl_alarm_profile1