System information

Table Of Contents
3. Commands
4821-A2-GB21-00 July 2004 3-29
Configure Interface DSL Profile Alarm Downstream Loss of Signal Seconds
Configure Interface DSL Profile Alarm Downstream Severely Error Seconds
Configure interface dsl-profile-alarm downstream-loss {loss} {profile_name}
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm downstream-loss command modifies the downstream
los-of-signal-seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
loss - if the number of LOSS events in a 15-minute interval meets or exceeds the
selected value (0–900 seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm downstream-loss 500 adsl_alarm_profile1
Configure interface dsl-profile-alarm downstream-ses {ses} {profile_name }
Minimum Access Level: Administrator
The configure interface dsl-profile-alarm downstream-ses command modifies the downstream
severely errored seconds required to generate an alarm.
profile_name – Identifies the ADSL Alarm profile to be modified.
ses - SNMP trap is sent if the number of severely errored seconds
events in a 15-minute interval meets or exceeds the selected value (0–900
seconds, where 0 disables the messages).
Example:
PDYN# configure interface dsl-profile-alarm downstream-ses 500 adsl_alarm_profile1