System information

Table Of Contents
3. Commands
4821-A2-GB21-00 July 2004 3-17
Configure Interface Console Data-Bits
Configure Interface Console Parity
Configure Interface Console Rate
configure interface console data-bits {7 | 8}
Minimum Access Level: Administrator
The configure interface console data-bits command sets the number of data bits in a byte on the
Console port.
data-bits – Valid choices are 7 and 8. The default is 8.
Example:
PDYN# configure interface console data-bits 7
configure interface console parity {even | none | odd}
Minimum Access Level: Administrator
The configure interface console parity command sets the parity bit type for the Console port.
parity – Valid choices are none, odd, and even. The default is none.
Example:
PDYN# configure interface console parity even
configure interface console rate {9600 | 19200 | 38400 | 57600 | 115200}
Minimum Access Level: Administrator
The configure interface console rate command sets the rate of the Console port in bps.
rate – Valid rates are 9600, 19200, 38400, 57600, and 115200. The default is 9600 bps.
Example:
PDYN# configure interface console rate 57600