System information

Table Of Contents
3. Commands
4821-A2-GB21-00 July 2004 3-7
Configure Factory Defaults
The configure factory command loads the factory default parameters into the
running configuration. The default parameters take immediate effect, but are not
saved. Execute the Save command to save the parameters to Non-Volatile
Random-Access Memory (NVRAM).
Configure Filter
Filters are used to restrict selected types of user data. A filter is made up of one or
more rules. Each rule that is defined for a filter is processed in the order defined in
the filter configuration command. As soon as one of the rules is matched, the
action for that rule is taken. The remaining rules, if any, are not checked.
In this system, the rules must be defined before the rule name can be specified in
the filter statement. This process is different from the process found in some
routers, where the rules are buried in the definition of the filter. A maximum of 16
rules can be defined for a filter.
configure factory
Minimum Access Level: Administrator
The configure factory command loads factory default parameters.
Example:
PDYN# configure factory
Notes:
This command will cause the factory default parameters to be loaded into the running configuration and
immediately take effect. The parameters will not be saved to NVRAM unless save command is issued
after this.
The reset to factory defaults is a two-step process. This prevents the Administrator from accidentally
destroying the configuration. After the administrator enters the configure factory command, a warning
message ("Warning: This will reset all configuration values. Proceed (yes/no) ?") is displayed. The
administrator must enter "yes" in order to change the configuration. To save the configuration to the
NVRAM, the administrator must also enter the save command.
Factory defaults include an out-of-band management address of 10.10.10.10, and an in-band
management address of 0.0.0.0. If you are managing the unit using a different IP address, your
connection is terminated upon execution of the configure factory command.
It is therefore recommended that this command be executed only from the Console port.