2. Write the carrier number on the slot label located
under each slot on the SDCP or cover plate.
Table 2-2
Carrier Address SDU S2 DIP Switches
S2 DIP
Carrier Number
S2
DIP
Switch
1* 2 3 4 5 6 7 8
S2-4 — — — — — — — —
S2-3 Off Off Off Off On On On On
S2-2 Off Off On On Off Off On On
S2-1 Off On Off On Off On Off On
* Factory default setting.
On is to the left as you face the rear of the carrier.
Off is to the right.
Table 2-3
Carrier Address Assignment
Highest Existing Network Address
First New
Carrier
DATAPHONE II ADp
C
arr
i
er
Address
11 – 48 01 – 32 2
51 – 88 33 – 64 3
91 – 128 65 – 96 4
131 – 168 97 – 128 5
171 – 208 129 – 160 6
211 – 248 161 – 192 7
251 – 288 193 – 224 8
291 – 328 225 – 256
*
* Start a new control channel when the carrier address
reaches this limit.
SDU CC/DC Operation
Set the SDU S1 DIP switch on the rear of the circuit
card (Table 2-4).
If connecting to . . .
Then set the . . .
Network control channel CC IN/CC OUT option
Diagnostic channel of an
upstream device
DC OUT/DC IN option
Table 2-4
SDU S1 DIP Switch
S1 DIP
Switch
CC IN/CC OUT* DC OUT/DC IN
S1-4 — —
S1-3 — —
S1-2 Off On
S1-1 Off Off
* Factory default setting.
On is to the left from the rear of the carrier.