Installation manual

Installing the Carrier and Assembly Components
2-153000-A2-GA31-F0 March 2001
Alarm Output Connection
To connect the alarm output to an external light or
buzzer:
Install the alarm light or buzzer and voltage source
as described in the instructions received with the
light/buzzer and voltage source.
Use the two ALARM terminals labeled E1 and E2
at the rear of the carrier to install two external
device leads.
Carrier 6
Carrier 5
Carrier 4
Carrier 3
Carrier 2
Carrier 1
495-12261-02
Customer
Supplied
Voltage
Source
Customer
Supplied
Alarm Light
or Buzzer
To Next
Cabinet
Rear of Cabinet
E4
SGRD
FGRD
E3 E1 E2
ALARM
" Procedure
1. Use pliers to pull the plastic covers off the E1 and
E2 terminals.
Plastic Cover
496-14656a-01
E2
2. Insert the end of the wire coming from the voltage
source and the end of a wire to be connected to the
next carrier into the E1 terminal. It is not
necessary to strip the wires.
Hollow Tube
Wire Ends
Tube Slot
496-14919b
3. Fit the wires into the slot in the terminal. Replace
the plastic cap on the terminal, fitting the wires
into the matching slot cut lengthwise in the cap.
NOTE
The last carrier to be connected
has one incoming lead for each
terminal.
Cover Slot
496-14919c