S-REGISTERS
Register Description Factory Setting Range
S0 Auto-Answer Ring Number 1 0 (Disable) or 1–255 rings
S2 AT Escape Character 43(+) 0–127 ASCII
S3 Carriage Return Character 13 0–127 ASCII
S4 Line Feed Character 10 0–127 ASCII
S5 Backspace Character 8 0–127 ASCII
S6 Blind Dial Pause 2 2–255 seconds
S7 No Answer Time-out 45 1–255 seconds
S8 “,” Pause Time for the Dial Modifier 2 0–255 seconds
S10 No Carrier Disconnect 2 0–254 (10ths of a second) or 255(Disable)
S12 Escape Sequence Guard Time 50 0–255 in 20-millisecond increments
S14 Asymmetric Rate (Dial) 0 0=Enable; 1=Disable
S18 Test Time-out 0(disabled) 0–255 seconds
S26 RTS/CTS Delay 0 0–255 seconds
S39 RX Buffer Disconnect Delay 0 0 (Disable) or 1–255 seconds
S40 Auto Make Busy 0 0 (Disable) or 1 (Enable)
S41 Dial Line Rate 27 1=14400(V.32bis); 2=12000(V.32bis);
3=9600(V.32bis); 4=7200(V.32bis);
5=4800(V.32bis); 6=2400(V.22bis); 7=1200(V.22);
8=1200(212A); 10=0–300(V.21); 11=0–300(103J);
20=19200(V.32terbo); 21=16800(V.32terbo);
27=33600(V.34); 28=31200(V.34);
29=28800(V.34); 30=26400(V.34);
31=24000(V.34); 32=21600(V.34);
33=19200(V.34); 34=16800(V.34);
35=14400(V.34); 36=12000(V.34);
37=9600(V.34); 38=7200(V.34); 39=4800(V.34);
40=2400(V.34)
S43 Train Time 0 0=Long; 1=Short
S44 Leased-Line Rate 25 1=14400(V.32bis); 2=12000(V.32bis);
3=9600(V.32bis); 4=7200(V.32bis);
5=4800(V.32bis); 6=2400(V22bis);
18=19200(V.32terbo); 19=16800(V.32terbo);
25=33600(V.34); 26=31200(V.34);
27=28800(V.34); 28=26400(V.34);
29=24000(V.34); 30=21600(V.34);
31=19200(V.34); 32=16800(V.34);
33=14400(V.34); 34=12000(V.34);
35=9600(V.34); 36=7200(V.34); 37=4800(V.34);
38=2400(V.34)
S45 Leased TX Level 0 0dBm–15dBm
S48 Leased-Line Carrier On Level 0 0=–43dBm; 1=–26dBm
S49 Buffer Disconnect Delay 10 0=Disable or 1–255 in 1-second increments
S55 Access from Remote 0 0=Enable; 1=Disable
S56 Remote Access Password 00 00–99
1st and 2nd digits
S57 Remote Access Password 00 00–99
3rd and 4th digits