SAFETY, REGULATIONS, AND CERTIFICATIONS
This chapter describes how to prepare your site for the installation of the
EtherXtend platform. It includes the following topics:
Grounding and isolation, page 13
Installation safety precautions on page 13
EMI Notices, page 16
ACTA Customer Information, page 16
Suppliers Declaration of Conformity, page 18
CE Marking, page 19
Contacting Global Service and Support, page 19
Technical Support, page 19
Service Requirements, page 20
Grounding and isolation
The EtherXtend system cards and subassemblies use an integrated frame and
logic ground system as follows:
The EtherXtend device and logic ground are bonded.
Cable shielding is terminated on the EtherXtend system device ground.
When the AC plug is not grounded, it is recommended to ground the device
using minimum 16-gauge wire to a building or earth ground.
Installation safety precautions
Avoid creating a hazardous condition by maintaining even weight distribution
within the device.
Maximum operating temperature should not exceed 65
0
C (149
0
F). Observe
the maximum recommended operating temperature as indicated here.