Grounding and isolation
The EtherXtend system cards and subassemblies use an integrated frame and
logic ground system as follows:
• The EtherXtend device and logic ground are bonded.
• Cable shielding is terminated on the EtherXtend system device ground.
When the AC plug is not grounded, it is recommended to ground the device
using minimum 16-gauge wire to a building or earth ground.
Installation safety precautions
Avoid creating a hazardous condition by maintaining even weight distribution
within the device.
Maximum operating temperature should not exceed 65
0
C (149
0
F). Observe
the maximum recommended operating temperature as indicated here.