Specifications

20 12000E IP Broadband Loop Carrier Installation Instructions IPD1-A2-ZZ40-20
Specifications
Important Safety Instructions
1 Read and follow all warning notices and instructions marked on the
product or included in the manual.
2 Do not attempt to service this product yourself, as opening or removing
covers may expose you to dangerous high voltage points or other risks.
Refer all servicing to qualified service personnel.
3 WARNING: This unit supports a redundant 48 VDC power input
connection. Disconnect both sources of input power before servicing.
Table 2: Specifications
Specification Criteria
Environment Operating Temperature:
–40° F to 149° F (–40° C to 65° C)
Storage Temperature:
–40° F to 158° F (–40° C to 70° C)
Humidity:
5 % to 95 %, non-condensing
Altitude:
–200 ft to 16,500 ft (–60 m to 5,000 m)
Physical 15.75" High x 17" Wide x 18" Deep
(40 cm High x 43.2 cm Wide x 46 cm Deep)
47 lbs (21.4 kg)
Power –48 VDC
30 amps maximum
Although actual power draw depends upon
chassis configuration, a fully loaded chassis
averages around 15 amps.
Regulatory Compliance NEBS:
GR-63-CORE; GR-1089-CORE
EMC:
FCC Part 15; CSA/C108.8; EN55022; EN55024
Safety:
CSA 22.2 No. 60950-1-03; EN60950-1:2001; CE
Marking
Telecom:
ACTA968 (Part 68); ICCS-03; TBR12; TBR13
!