Product Instructions

4
VII. Product transport
The packaged products can be transported by ordinary means of transport, the
ambient temperature in transit should be in the range of -10℃-55℃, the relative
humidity is less than 95%, and the strong shock, vibration, extrusion and moisture
should be prevented during transportation.
VIII. Product storage
1. Avoid splashing rain and direct sunlight;
2. Should be kept in a dry, well-ventilated, non-corrosive room.
3. The ambient temperature is -10℃-55℃ and the relative humidity is ≤95%.
4. Avoid strong electric field or strong magnetic field;
5. Storage site without strong vibration, shock.
6. Packing more than 10 cm, and from floor to wall more than 50 cm;
IX. Analysis of basic faults
Table 1: List of Fault Analysis
Ordinal
Fault content
Solution
1
No alarm when the label is
held at the exit
1. First check the battery power of
the Baby Tag in the software to
check if there is electricity.
2. Whether the baby's anti-theft
system has added the label to the
hospital, and the exit alarm can be
turned on.
3. Check whether the wristband is
in good contact, and the contact of
the anti-pull spring point is good.
4. Change wristband or use paper
clip short to see if recovery alarm.
5. If there is no response to the
previous trial, you need to return
our company to repair.
2
Cut the wristband and
1.Check whether the label has a
low power alarm, low power may
be triggered by mistake cut alarm.