Quick Guide
Table Of Contents
4 
Wiring 
Before installation, plan wiring for power cable, network cable, door lock cable, 
wiegand cable, alarm cable, RS485 cable, etc. The number of cables depends on the 
actual networking conditions. See the figures below for wiring between the terminal 
and other devices. 
N
OTE! 
•
Input devices in the diagrams below refer to devices that send signals to the access 
control terminal. Output devices refer to devices that receive signals from the 
terminal. 
•
  For the wiring terminal of each device, see the operation 
manual of the device or 
consult related manufacturers. 
 Wiring Schematic Diagrams (without Security Module) 
The face recognition access control terminal can be also connected to a security 
module. The figure below shows the wiring of the security module. 
Power input
Alarm input 
Alarm output 
RS485
Wiegand output
Wiegand input
Door lock
VDD12V  
Red
GND 
Black
+12V
GND
GND 
Black
ALM_IN2 
White/Purple
ALM_IN1 
Purple
ALM_OUT_NO 
White/Blue
ALM_OUT_NC 
Gray
ALM_OUT_COM 
White/Orange
RS485_A 
Orange
RS485_B 
Yellow
GND 
Black
WIEGAND_IN0  
Blue
WIEGAND_IN1  
White
GND 
Black
WIEGAND__OUT0 
Brown
WIEGAND__OUT1 
Green
LOCK_NC 
Pink
LOCK_COM 
White/Yellow
LOCK_NO 
White/Green
GND 
Black
SEN_ INPUT 
Light Green
BUTTON_INPUT 
Yellow/Black
PRESS
TO EXIT
+
+
-
-
+
-
Face Recognition Access Control Terminal
-
+
Network interface
Door opening button
Electric strike
Door magnetic 
sensor
Power supply
Electric drop bolt lock
/Magnetic lock
Access 
controller
Wiegand
card reader
Alarm output device
Alarm output device
Alarm input device
Alarm input device
Power 
supply
Digital detection module