Face Recognition Access Control Terminal Quick Guide V1.
Contents 1. Packing List ............................................................................................ 3 2. Product Overview .................................................................................. 3 2.1 Appearance and Dimension......................................................................... 4 2.2 Structure Description ................................................................................... 5 3. Device Installation............................................
1. Packing List The contents may vary with models, please see the actual model for details. No. Name Qty Unit 1 Face recognition access control terminal 1 PCS 2 Screw component 2 Set 3 Power adapter 1 PCS 4 Power cable 1 PCS 2. Product Overview The face recognition access control terminal is a kind of access control device with precise recognition rate, large storage capacity and fast recognition.
2.1 Appearance and Dimension The actual device appearance shall prevail. The figure below shows the dimension of the device.
2.2 Structure Description The figure below shows the structure of the device. The actual device shall prevail. Type A : 1. Range sensor 2. Temperature sensor 3. Light supplement lamp 1 4. Camera 1 5. Infrared light supplement lamp 6. Camera 2 7. Light supplement lamp 2 8. Display screen 9. Pass-through indicator 10. Microphone 11. Card reading area 12. Loudspeaker 13. Reboot button 14. USB 2.0 15.
Type B : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1. Range sensor 2. Temperature sensor 3. Light supplement lamp 1 4. Camera 1 5. Infrared light supplement lamp 6. Camera 2 7. Light supplement lamp 2 8. Display screen 9. Pass-through indicator 10. Microphone 11. Card reading area 12. Loudspeaker 13. Reboot button 14. USB 2.0 15.
3. Device Installation 3.1 Installation Environment Try to avoid intense direct light and intense backlighting scenes when installing the device. Please keep the ambient light bright. 3.2 Device Wiring 1 Wiring Embedding Before installing the face recognition access control terminal, plan the layout of cables, including the power cable, network cable, door lock cable, and alarm cable. The number of cables depends on the actual networking conditions. For details, see Wiring Description.
Figure 3-1 Wiring Schematic Diagrams Wiegand input Wiegand output Alarm input device Alarm input device Alarm output ALARM_OUT_NC GREEN ALARM_OUT_COM WHITE/PURPLE device - Power supply ALARM_OUT_NO WHITE/ORANGE Alarm output device GND BLACK WG_IN_D0 WHITE/BLACK WG_IN_D1 WHITE/RED WG_OUT_D0 BLUE WG_OUT_D1 RED GND BLACK Wiegand card reader GND + Door status switch Reserved Cathode lock PRESS USB2.
3.3.2 Install Power Supply 1. Open the two cover plates at the middle and bottom of the pole. 2. Install the power supply. Lead the tail cables into the middle hole and out from the hole on the bottom cover plate. 3. Close the middle and bottom cover plates.
3.3.3 (Optional) Ground Mount NOTE! Make sure the ground surface is hard and even. 1. Mark holes on the ground, as illustrated below. 50mm cable hole diameter is recommended for easier cable threading. Cable holes Fixing hole 2. Use an electric drill to drill 100mm deep holes at the marked positions. 3. Insert M8X80 expansion bolts into the four fixing holes. Make sure the top of the expansion bolts is slightly above the ground.
4. Align the holes on the base with the expansion bolts on the ground, adjust the direction of the device, and then use a wrench to fasten the nuts to secure the pole. d Groun 3.3.4 (Optional) Adjust Angle 1. Loosen the four adjusting screws with a L-shaped hex key. Adjusting screw 2. Adjust the angle of the face recognition access control terminal. 3. Tighten the adjusting screws.
4. Device Startup After the device is installed correctly, connect one end of the power adapter (purchased or prepared) to the mains supply and the other end to the power interface of the face recognition access control terminal, and then start the device. The display screen of the outdoor monitor is energized and lights up, and the live view is displayed on the screen, indicating that the device is started successfully. 5.
6. Personnel Management The face recognition access control terminal supports personnel management on the Web interface and GUI interface. ⚫ Personnel management on the Web interface On the Web interface, you can add persons (one by one or in batches), modify person information, or delete persons (one by one or together). The detailed operations are described as follows: 1. Log in to the Web interface. 2.
7. Appendix 7.1 Face Recognition Precautions 7.1.1 Face Photo Collection Requirements ⚫ General requirement: bareheaded full face photo, with the front side facing the camera. ⚫ Range requirement: The photo should show the outline of a person's both ears and cover the range from the top of the head (including all hair) to the bottom of the neck. ⚫ Color requirement: true color photo.
Figure 7-1 Face Match Position Note: Range of recognizable distance: 0.5m to 2m. Wall 2m Matchable range 1.5m 1m 1 2 0.5m Ground 0.5m 1m 1.5m 2m NOTE! The face match position should be within the recognizable range shown in the figure. If face match fails in area 1 shown in the figure, move backward. If face match fails in area 2 shown in the figure, move forward.
7.1.3 Face Match Posture 1 Facial Expression To ensure the accuracy of face match, keep natural expression during the match (as shown in the figure below). Figure 7-2 Correct Expression 2 Facial Posture To ensure the accuracy of face match, keep the face facing the recognition window during the match. Avoid the head to one side, side face, head too high, head too low, and other incorrect postures.
Disclaimer and Safety Warnings Copyright Statement ©2020 Zhejiang Uniview Technologies Co., Ltd. All rights reserved. No part of this manual may be copied, reproduced, translated or distributed in any form by any means without prior content in writing from Zhejiang Uniview Technologies Co., Ltd (referred to as Uniview or us hereafter). The product described in this manual may contain proprietary software owned by Uniview and its possible licensors.
⚫ Uniview reserves the right to change any information in this manual without any prior notice or indication. Due to such reasons as product version upgrade or regulatory requirement of relevant regions, this manual will be periodically updated. Disclaimer of Liability ⚫ To the extent allowed by applicable law, in no event will Uniview be liable for any special, incidental, indirect, consequential damages, nor for any loss of profits, data, and documents.
⚫ Enable HTTPS/SSL: Use SSL certificate to encrypt HTTP communications and ensure data security. ⚫ Enable IP address filtering: Allow access only from the specified IP addresses. ⚫ Minimum port mapping: Configure your router or firewall to open a minimum set of ports to the WAN and keep only the necessary port mappings. Never set the device as the DMZ host or configure a full cone NAT.
⚫ Make sure the power supply provides a stable voltage that meets the power requirements of the device. Make sure the power supply's output power exceeds the total maximum power of all the connected devices. ⚫ Verify that the device is properly installed before connecting it to power. ⚫ Do not remove the seal from the device body without consulting Uniview first. Do not attempt to service the product yourself. Contact a trained professional for maintenance.
➢ Chemical Burn Hazard. This product contains a coin cell battery. Do not ingest battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. ➢ Keep new and used batteries away from children. ➢ If the battery compartment does not close securely, stop using the product and keep it away from children. ➢ If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Better Security, Better World www.uniview.com globalsupport@uniview.