3. Use a drill to drill two holes with the
depth of 30mm and diameter of 6mm to
6.5mm on the wall.
Note
Avoid embedded wires in the wall during drilling!
4.
Embed expansion bolts inside the
two installation holes on the wall.
5. Bracket.
Normal InstallationAlign holes on the bracket with installation holes on the wall
and the 86*86mm wall-mounted junction box and use the Phillips screwdriver to
tighten the screws clockwise to fasten the bracket.
Waterproof InstallationThe waterproof installation process is basically the same
as the normal installation process. You need to fasten the bracket and waterproof
hood together, for detail, see figure below. After the waterproof installation is
completed, apply enough silicone rubber along the gap between the edge of the
waterproof hood and the wall(left, top and right). Silicone rubber must be
continuous.
(without waterproof hood) (with waterproof hood)
Wall
Wall