3 Product installation
3.1 Installation requirements
In actual use, HS_C09959 should be installed in a higher position to achieve better
transmission and coverage. Moreover, the higher the installation height, the smaller the
device spacing should be, as shown in Figure 3-1.
Figure 3-1 HS_C09959 installation
The recommendations for installation scenario are as follows:
When the shelf height is ≤3m, H in Figure 3-1 is recommended to 3m ~ 5m, and
the coverage radius R is 10 ~ 15m. It is recommended that the installation distance
of two Hanshow APs is about 25m, and at least 5m;
When the shelf height is 3 ~ 5m, H in Figure 3-1 is recommended to 5 ~ 8m, and
the coverage radius R is 7 ~ 12m. It is recommended that the installation distance
of two Hanshow APs is about 20m and at least 5m.
Notice:
If shelf height exceeds 5m, the installation height of AP is determined according
to the actual situation;
The installation height of AP should be higher than shelf height to avoid signal
occlusion.